<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns="http://purl.org/rss/1.0/" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel rdf:about="http://hdl.handle.net/20.500.12701/2065">
    <title>DSpace Собрание: The open access Journal of Physics: Conference Series (JPCS) provides a fast, versatile and cost-effective proceedings publication service.</title>
    <link>http://hdl.handle.net/20.500.12701/2065</link>
    <description>The open access Journal of Physics: Conference Series (JPCS) provides a fast, versatile and cost-effective proceedings publication service.</description>
    <items>
      <rdf:Seq>
        <rdf:li rdf:resource="http://hdl.handle.net/20.500.12701/2149" />
        <rdf:li rdf:resource="http://hdl.handle.net/20.500.12701/2066" />
      </rdf:Seq>
    </items>
    <dc:date>2026-04-14T08:35:21Z</dc:date>
  </channel>
  <item rdf:about="http://hdl.handle.net/20.500.12701/2149">
    <title>Promising directions of information technologies applications for improving of control and measuring devices in medical industry</title>
    <link>http://hdl.handle.net/20.500.12701/2149</link>
    <description>Название: Promising directions of information technologies applications for improving of control and measuring devices in medical industry
Авторы: Zolkin, A L; Munister, V D; Bogaevskaya, O Yu; Yumashev, A V; Kornetov, A N
Краткий осмотр (реферат): The article deals with the problems of functioning and improvement of measuring and control devices in the medical industry. The classification, principles of organization of specialized, multifunctional and single-functional medical instrument and computer systems are considered. A model for solving the problem of scalability and availability through the use of non-relational data management systems that combine methods for achieving atomicity and data consistency is proposed. The promising diagnostic methods in medicine are described. The importance of a prompt assessment of the patient's condition is emphasized. The optimization and modernization of the digital radiography using modern machine learning algorithms are given and justified.</description>
    <dc:date>2021-01-01T00:00:00Z</dc:date>
  </item>
  <item rdf:about="http://hdl.handle.net/20.500.12701/2066">
    <title>The optical and electrical non-invasive methods of measurement for glucose concentration in biological liquids</title>
    <link>http://hdl.handle.net/20.500.12701/2066</link>
    <description>Название: The optical and electrical non-invasive methods of measurement for glucose concentration in biological liquids
Авторы: Zhexenbayev, Y K; Bulembayev, T D; Gorst, A V; Zavyalova, K V; Mironchev, A S; Yurchenko, E V
Краткий осмотр (реферат): The article describes the radio-wave and optical methods of determining glucose concentration. The radio-wave method is based on the use of a sensor with a resonant frequency that is displayed when in contact with highly lossy materials and with an extended near-field zone in the resonance area. The optical method is based on studying the influence of glucose concentration (0–20 mmol/l) in bidistilled water on absorption spectra in the range of 190-1000 nm. The article presents the results of the experimental test of the near-field sensor with the pre-produced biological media imitating the human body tissues, and the results of the optical method demonstrate the possibility to measure the concentration with the use of an optical emitter with a wave length of 830 nm.</description>